MINERAL WOOL Technical information
thermaRock-WR pipe insulation
-
ThermaRock-WR pre-formed pipe insulation has been tested by independent SCC-accredited labs.
ASTM C547: Standard Specification for Mineral Fiber Pipe Insulation
ASTM C335 / C177: Steady State Heat Transfer Properties of Horizontal Pipe Insulation
ASTM C356: Linear Shrinkage of Preformed High Temperature Insulation Subject to Soaking Heat
ASTM C411: Hot-Surface Performance of High Temperature Thermal Insulation.
ASTM C447: Maximum Use Temperature of Insulations.
ASTM C1045: Thermal Transmission Properties from Steady-State Heat Flux.
-
ThermaRock-WR pre-formed pipe insulation has been tested by independent SCC-accredited labs.
ASTM C795 / C871: Thermal Insulation for Use in Contact with Stainless Steels.
ASTM C692: Influence of Thermal Insulation on External Stress Corrosion Cracking.
ASTM C1104: Water Vapor Sorption by Unfaced Mineral Fiber.
ASTM C1617: Evaluation of Accelerated Corrosion of Extracted Solutions Containing Leachable Ions on Aqueous Corrosion of Metals.
-
ThermaRock-WR pre-formed pipe insulation has been tested by independent SCC-accredited labs.
CAN/ULC S102: Standard Method of Test for Surface Burning Characteristics of Building Materials.
UL 723: Standard Test for Surface Burning Characteristics of Materials.
thermawrap-WR flexible pipe & EQUIPMENT INSULATION
-
ThermaWrap-WR flexible pipe wrap insulation has been tested by independent SCC-accredited labs.
ASTM C553: Standard Specification for Mineral Fiber Blanket Thermal Insulation
ASTM C177: Steady State Heat Transfer Properties of Horizontal Pipe Insulation
ASTM C411: Hot-Surface Performance of High Temperature Thermal Insulation.
ASTM C447: Maximum Use Temperature of Insulations.
ASTM C1045: Thermal Transmission Properties from Steady-State Heat Flux.
ASTM C1101: Classifying the Flexibility or Rigidity of Mineral Fiber Blanket and Board Insulation.
-
ThermaWrap-WR flexible pipe wrap insulation has been tested by independent SCC-accredited labs.
ASTM C795 / C871: Thermal Insulation for Use in Contact with Stainless Steels.
ASTM C692: Influence of Thermal Insulation on External Stress Corrosion Cracking.
ASTM C1104: Water Vapor Sorption by Unfaced Mineral Fiber.
ASTM C1617: Evaluation of Accelerated Corrosion of Extracted Solutions Containing Leachable Ions on Aqueous Corrosion of Metals.
-
ThermaWrap-WR flexible pipe wrap insulation has been tested by independent SCC-accredited labs.
CAN/ULC S102: Standard Method of Test for Surface Burning Characteristics of Building Materials.
UL 723: Standard Test for Surface Burning Characteristics of Materials.
-
ThermaWrap-WR flexible pipe wrap insulation is available with the following facing options:
Single-sided reinforced foil facing (RFF)
Galvanized wire mesh (single-sided or double-sided)
Stainless steel wire mesh (single-sided or double-sided)
Single-sided black woven srcim.
thermaslab-WR semi-rigiD VESSEL & TANK INSULATION
-
ThermaSlab-WR semi-rigid insulation has been tested by independent SCC-accredited labs.
ASTM C612: Mineral Fiber Block and Board Insulation.
ASTM C177: Steady State Heat Transfer Properties of Horizontal Pipe Insulation.
ASTM C356: Linear Shrinkage of Pre-Formed High Temperature Insulation.
ASTM C411: Hot-Surface Performance of High Temperature Thermal Insulation.
ASTM C447: Maximum Use Temperature of Insulations.
ASTM C1045: Thermal Transmission Properties from Steady-State Heat Flux.
ASTM C1101: Classifying the Flexibility or Rigidity of Mineral Fiber Blanket and Board Insulation.
-
ThermaSlab-WR semi-rigid insulation has been tested by independent SCC-accredited labs.
ASTM C795 / C871: Thermal Insulation for Use in Contact with Stainless Steels.
ASTM C692: Influence of Thermal Insulation on External Stress Corrosion Cracking.
ASTM C1104: Water Vapor Sorption by Unfaced Mineral Fiber.
ASTM C1617: Evaluation of Accelerated Corrosion of Extracted Solutions Containing Leachable Ions on Aqueous Corrosion of Metals.
-
ThermaSlab-WR semi-rigid insulation has been tested by independent SCC-accredited labs.
CAN/ULC S102: Standard Method of Test for Surface Burning Characteristics of Building Materials.
UL 723: Standard Test for Surface Burning Characteristics of Materials.
MINERAL WOOL technical data
THERMAROCK-WR MANDREL WOUND PIPE INSULATION (MINERAL WOOL)
THERMAWRAP-WR FLEXIBLE BLANKET INSULATION (MINERAL WOOL)
THERMASLAB-WR SEMI-RIGID TANK & VESSEL INSULATION (MINERAL WOOL)
THERMABLOCK-WR RIGID BOARD INSULATION (MINERAL WOOL) (TO BE PUBLISHED; CONTACT FOR INFO)